Toolsky

Free Online Tools & Utilities for Every Task.

Illuminance Converter

A precise tool to convert between various illuminance units like Lux, Foot-candles, and Phots.

Light is specified in different units depending on where in the world a plan, a datasheet or a building code was written. European lighting documents talk in lux, American ones often use foot-candles, and older technical literature throws in phots. This illuminance converter moves between those units precisely, so a value written for one market can be read correctly in another without error-prone mental arithmetic.

Illuminance, in plain terms

Illuminance describes how much light actually lands on a surface. It is luminous flux divided by area: a lumen spread over one square metre gives one lux, a lumen over one square foot gives one foot-candle, and a lumen over one square centimetre gives one phot. Because the areas differ so much, the numbers differ wildly for the same light — one phot equals 10,000 lux, and one foot-candle equals 10.7639 lux. Illuminance is not the same as the total light a lamp produces (that is luminous flux, in lumens), nor the brightness you perceive looking at a source (that is luminance). It answers one practical question: how bright is the surface in front of you?

The units this converter handles

The tool is built around the units that appear in real specifications and measurements:

  • Lux (lx) — the SI unit, standard across Europe, Asia and scientific work; what most light meters display.
  • Foot-candle (fc) — the imperial unit still used in US building codes, IES recommendations and American product datasheets.
  • Phot (ph) — the older CGS unit, now rare in new documents but common in archival photography and optics literature.
  • Conversions run in every direction between the units, with the precision needed for specification work rather than rough estimation.

If your document instead deals with how bright a surface appears — candelas per square metre and related units — that is the neighbouring quantity covered by the Luminance Converter.

How to convert an illuminance reading

  1. Read the value you need to convert and note its unit exactly as written in the source document.
  2. Enter the number into the converter.
  3. Select the unit you are converting from — lux, foot-candles or phots.
  4. Select the target unit your own document, code or client requires.
  5. Read the converted result and round it sensibly: whole numbers are normal for lux in building work, while small foot-candle values may need one or two decimals.
  6. Write the result down together with its unit, so nobody downstream has to guess which scale you used.

Worked example: an office lighting reading

Suppose a European lighting plan specifies an average of 500 lux at desk height, and the American contractor on the project works in foot-candles. Since one foot-candle equals 10.7639 lux, divide: 500 ÷ 10.7639 = 46.45 foot-candles. So the plan's 500 lux requirement and a US specification of roughly 46.5 fc describe exactly the same light. Running it through the converter gives that figure instantly and removes the risk of the classic blunder — treating lux and foot-candles as interchangeable, which would leave the room lit to barely a tenth of the intended level (or ten times too bright in the other direction).

Where illuminance conversions come up in practice

Lighting designers live with this daily: a luminaire datasheet from a European manufacturer lists expected lux levels, while the local code official checks the design against foot-candle minimums. Facility managers auditing a warehouse against safety recommendations hit the same split when the audit template comes from another country. Photographers and videographers meet phots and lux in older exposure literature when adapting vintage guidance to modern LED panels. Aquarium and indoor-gardening enthusiasts convert published light requirements for plants and corals, which different communities stubbornly document in different units. Even property work crosses the boundary — a home inspector comparing a light-meter reading against a foreign standard needs the number translated, not guessed. In each case the underlying light is identical; only the ruler changes, which is why a precise converter matters more than a memorised approximation.

Mistakes that quietly wreck lighting figures

The most expensive error is confusing illuminance with luminous flux: a 1,000-lumen lamp does not produce 1,000 lux everywhere — the lux level depends on how widely that light spreads and how far the surface is from the source. Doubling the distance quarters the illuminance, by the inverse-square law, so a reading taken close to a fitting cannot be quoted as the level at the desk. A second mistake is converting with the rounded "times ten" shortcut between lux and foot-candles and then treating the result as specification-grade; the true factor is 10.7639, and the error compounds in compliance work. Finally, watch the phot: because one phot is ten thousand lux, a misplaced conversion there is not a rounding issue but a four-orders-of-magnitude disaster. Converting floor areas for a lighting layout is easier with the Area Converter open alongside.

Frequently Asked Questions About Illuminance Units

What is the exact relationship between lux and foot-candles?

One foot-candle equals 10.7639 lux, because a square foot is smaller than a square metre. To go from lux to foot-candles, divide by 10.7639; to go the other way, multiply.

Is a lux the same as a lumen?

No. A lumen measures the total light a source emits; a lux measures how much of that light lands on each square metre of a surface. The same lamp gives high lux nearby and low lux far away.

Why do American documents still use foot-candles?

US building practice, codes and the IES recommendations were built around imperial measurements, and the foot-candle remains the working unit in that ecosystem even though lux dominates internationally.

Does anyone still use phots?

Rarely in new work, but phots appear in older photography, microscopy and optics texts. Because one phot equals 10,000 lux, archival values need careful conversion before they can be compared with modern readings.

How many lux does an office actually need?

Commonly cited guidance puts general office work around 300–500 lux at desk level, with lower levels for corridors and higher levels for detailed drawing or inspection tasks. Always check the specific standard your project must meet.

Can a phone app replace a lux meter for converted readings?

Phone light sensors give rough estimates useful for comparisons, but they are not calibrated instruments. If a converted value will be used for compliance or a dispute, measure with a proper meter first, then convert.

Does converting change the precision of my measurement?

No — conversion is exact arithmetic. The result is only as accurate as the original reading, so it is sensible to round converted values to a similar number of significant figures.

Spec sheets stop being a translation problem

Lux, foot-candles and phots are three dialects for the same physical fact. Keep this converter next to your documents and the numbers from any country read as if they were written for yours.